【Features】
You can greatly improve trouble analysis and work efficiency on site.
It can contribute to trouble analysis on site.
Digital management saves labor on measurement work (Direct input function to Excel when Z3210 is installed) and improves work efficiency.
Prevents incorrect insertion of test leads and is safe and secure (terminal shutter).
The test lead and cap are integrated.
High dustproof and waterproof performance (compatible with international standard IP54).

【Use】
For electrical work, etc.

【Specification】
DC voltage (V): 1000
AC voltage (V): 1000
DC current (A): 10
AC current (A): 10
Resistance (Ω): 60M
DC current (mA): 600
AC current (mA): 600
Detection method: True RMS rectification (RMS)
Power source (V): AA alkaline batteries (LR6) x 3 (included)

【Specification2】
Safety: EN61010 / EMC: 61326 / Dustproof and waterproof: IP54
[DC voltage range] 600.0 mV to 1000 V, 5 ranges, basic accuracy: ±0.15% rdg. ±2 dgt. [AC voltage range] 6.000 V to 1000 V, 4 ranges, frequency characteristics: 40 Hz to 1 kHz, basic accuracy 40 Hz - 500 Hz: ±0.9 % rdg. ±3 dgt. (effective value rectification, crest factor 3 or less)
[DC + AC voltage range] 6.000 V to 1000 V, 4 ranges, frequency characteristics: DC, 40 Hz to 1 kHz, basic accuracy DC, 40 Hz - 500 Hz: ±1.0 % rdg. ±13 dgt. (effective value rectification, crest factor 3 or less)
[LoZ V] 600.0 V, 1 range, frequency characteristics: DC, 40 Hz to 1 kHz, basic accuracy DC, 40 Hz - 500 Hz: ±1.0 % rdg. ±13 dgt. (effective value rectification, crest factor 3 or less)
[Resistance range] 600.0 Ω to 60.00 MΩ, 6 ranges, basic accuracy: ±0.7% rdg. ±3 dgt.
[DC current range] 600.0 mA to 10.00 A, 3 ranges, basic accuracy: ±0.5% rdg. ± 3 dgt. [AC current range] 600.0 mA to 10.00 A, 3 ranges, basic accuracy 40 Hz - 500 Hz: ±1.4 % rdg. ±3 dgt. (effective value rectification, crest factor 3 or less) AC clamp measurement)] 10.00 A to 1000 A, 7 ranges, basic accuracy 40 Hz - 500 Hz: ±0.9 % rdg. ±3 dgt. + Clamp-on probe measurement accuracy
[Capacitance range] 1.000 μF ~ 10.00 mF, 5 ranges, basic accuracy: ±1.9 % rdg. ±5 dgt. [Continuity check] Continuity ON threshold: 25 Ω, Continuity OFF threshold: 245 Ω, Response time: 0.5 ms or more [Diode test] Open voltage: 2.0 V or less, Measurement current: 0.2 mA, Forward threshold: 0.15 V to 1.8 V
[Voltage frequency range] 99.99 Hz to 99.99 kHz, 4 ranges (limited by minimum sensitivity voltage), Basic accuracy: ±0.1 % rdg. ±1 dgt. [Current frequency range] 99.99 Hz to 9.999 kHz, 3 ranges (limited by minimum sensitivity current), basic accuracy: ±0.1 % rdg. ±1 dgt. Maximum display: 6000 counts

【Material/Finish】


【Set contents/accessories】
Test lead L9300 x 1
Instruction manual x 1
AA alkaline battery (LR6) x 3
Usage precautions x 1

【caution】